MENU
products
  1. Home
  2. --
  3. Industrial boilers

ignition electrodes for boiler

Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

Pilot Assemblies & Ignition Electrodes - OEM Boiler Par

Pilot Assemblies & Ignition Electrodes. The Kewanee-designed and built burner went through numerous and frequent design changes, especially during the years 1985-1995, which affected both pilot and diffuser design and usage. Only OEM Boiler Parts has the original Kewanee Engineering and Sales Order records to be able to determine exactly

How to remove, replace, clean electrodes in condensing

Click to v

Click to view3:09Aug 18, 2016· How to remove, replace, clean electrodes in condensing boiler Junkers (Worcester) Fix and Drive setting electrodes and replacing nozzle How to check ignition on the Baxi Duo-tec & Baxi

Ignition Electrodes and Ionisation Probe - H Type Igniti

Ignition Electrodes and Ionisation Probe. From world class manufacturers Brahma s.p.a. and Ivalox,Classic Group offer an exhaustive range of Ignition & Ionisation Electrodes of different diameters and ceramic length, also Joint ( H Type )Electrodes as per requirement for Oil & Gas Burners & Boilers. Classic Enterprises, weare one of the leading supplier of Oil & Gas Burner Ignition Electrodes

Boiler Electrodes For Ignition And Flame Sensi

Electrodes are used in boilers, gas fire and other gas appliance. There are two type of electrodes - ignition electrode also known as a spark electrode and flame sensing electrodes also known as an ionisation electrode. The ignition electrode is used for creating a spark when a high voltage is applied to it. This the ignites the burner.

Ignition Electrode - H Type Ignition Electro

Author: Fix and Drive Ignition Electrode. Prominent & Leading Manufacturer and Supplier from Ahmedabad, we offer Ignition Electrode such as Ignition Electrodes, Ignition Electrodes & Ionization Probe, Riello Burner Ignition Electrode, H Type Electrode, H Type Electrodes and Kiln Spark Plug Electrode.

How to clean boiler electrodes | Viessma

The ignition electrodes and ionisation probe are usually positioned together in the combustion chamber of a boiler. Ignition electrodes can be used as ionisation probes and vice versa. Either of these sensors can become dirty over time, which could prevent them from working.

Amazon.com: Weil-McLain 383500045 Ignition Electrode K

Buy Weil-McLain 383500045 Ignition Electrode Kit: Ignition Parts - Amazon.com FREE DELIVERY possible on eligible purchases

Understanding Transformers | Beckett Cor

Mounts electrodes and insulates each electrode from ground. Must be clean and not cracked. 12. Arc gap and electrodes: Specified gap (1/8″ – 5/32″) allows arc to jump to other terminal and ignite oil droplets. Too close causes delayed ignition. Too wide results in no ignition and possible damage to secondary. Clean and properly adjust.

Ignition Electrodes | RK Instruments And Contro

Ignition Electrodes manufacturers, suppliers, exporters and also known as Ignitor, Igniter, Ionization Electrode, Spark Rods, Flame Ionisation Probes, Flame Rods and Flame Sensors. These industrial ignition electrodes can be developed as per customer’s specification or design. Tubular ceramic insulators are available in diameter 6 mm to diameter 15 mm, length 50 mm (2 Inch) to 1000 mm (40

What are ignition electrodes on boilers - Answe

User rating: 4.6/5 ignition electrodes implies two are installed. two electrodes implies an oil fired boiler. the electrodes are tied electrically to the secondary windings of a high voltage transformer. during

Cleaver-Brooks | Electrode Steam Boil

High-voltage steam boiler ; 4.16-25 kV – up to 188,000 lb/hr; 100-500 psi; No local emissions; Fast response time; The Model CEJS is a high-voltage, jet-type electrode steam boiler that utilizes properties of water to conduct electrical current and generate steam.

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration

Copyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.

top