MENU
products
  1. Home
  2. --
  3. Industrial boilers

standard boiler feed water

Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

Boiler Water Quali

Boiler Water Quality Boiler Chemicals are used to ensure proper Boiler Water Quality in boilers. The below table is the Total Dissolved Solids or TDS, Alkalinity, and Hardness versus Boiler Pressure. First, knowing the water source is important, whether it is from ponds, rivers, ground wells, or city water.

DRAFT BOILER/FEEDWATER GUIDELIN

pitting can result with possible rupture of boiler condensate piping or boiler tubes. 3.3.4 Rusty water in the boiler gage glass is a sure sign of acid corrosion in the boiler feedwater/condesate system or in the boiler itself. 3.3.5 Make-up water is the major source of carbon dioxide. The first priority is to minimize the amount of make-up water.

IS 10496: Specification for Feed Water, Boiler Water a

Jan 08, 2013· Name of Legally Binding Document: 10496: Specification for Feed Water, Boiler Water and Condensate for High Pressure Boilers Name of Standards Organization: Bureau of Indian Standards (BIS) LEGALLY BINDING DOCUMENT. Addeddate 2013-01-08 19:17:05 Identifier gov.law.is.10496.1983

Standard Specification For Boiler Compound And Wat

for boiler compound and water treating chemicals institutional water treatment program kent w. smothers, feed equipment. commodity no: 2900-141-0033 sodium tripolyphosphate, anhydrous, by the use of the standard phenol test or by measurement of the threshold odor reduction in the water to be treated.

What Is a Boiler Feed Water Treatment System and How Do

Sep 26, 2016· For industrial companies using a boiler for its facility, some type of boiler feed water treatment system is usually necessary to ensure an efficient process and quality steam generation. The most appropriate boiler feed water treatment system will help the facility avoid costly plant downtime, expensive maintenance fees, and boiler failure as a result of scaling, corrosion, and fouling of the

Boiler Feed Water and Boiler Water - EWT Water Technolo

File Size: 272KB EN 12953-10 / Shell boilers – Requirements for boiler feed water and boiler water quality; national codes and standards: BS 2486 / Recommendations for Treatment of Water for Steam Boilers and Water Heaters (United Kingdom, obsolete) TRD 611 / Feed Water and Boiler Water of Group IV Steam Generators (Germany, obsolete)

ASME Guidelines for Water Quality in Modern Industri

File Size: 1MB Boiler feed water ASME Guidelines for Water Quality in Modern Industrial Water Tube Boilers for Reliable Continuous Operation Boiler Water. Created Date:

Boiler Water & Feed Water Analysis | Chemistry Laborato

Standard Boiler Water Analysis & Feedwater Analysis. This product gives you the option to test the quality of your boiler water or your feedwater, your feedwater may be from your hotwell or from your water source in the case of locomotive boilers.

Boiler water Limit:- - Altr

Feed Water & Boiler water Characteristics as per IS:10392-1982 1.FEED WATER Parameters Upto 20 Kg/cm2 21 Kg/cm2 to 39 Kg/cm2 40 Kg/cm2 to 59 Kg/cm2 Unit Total Hardness <10 <1.0 <0.5 ppm as CaCO 3 pH Value 8.5-9.5 8.5-9.5 8.5-9.5 Dissolved Oxygen 0.1 …

Feed Water - Chemistry Limits - Engineering ToolB

Feed Water Treatment to Avoid Corrosion - Make-up water to steam boilers should be treated with oxygen scavengers to avoid serious corrosion problems; Maximum Flow Velocities in Water Systems - Water velocities in pipes and tubes should not exceed certain limits; Steam Boiler Rating and Feed Water Temperature - Boiler output and feed water

ASME - International Boiler and Pressure Vessel Code

Power Boilers. This Section provides requirements for all methods of construction of power, …

VGB-Standard Feed Water, Boiler Water and Steam Quali

Power Boilers. This Section provides requirements for all methods of construction of power, … VGB-Standard Feed Water, Boiler Water and Steam Quality for Power Plants / Industrial Plants VGB-S-010-T-00;2011-12.EN Third edition 2011 (formerly VGB-R 450 Le) Editor: VGB PowerTech e.V. Publisher: VGB PowerTech Service GmbH Verlag technisch -wissenschaftlicher Schriften Klinkestr. 27-31, 45136 Essen Phone: +49 201 8128-200

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration

Copyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.