Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

Laying Up a Boiler by the Wet Method - tpub.c

The feedwater used to fill the boiler is deaerated as much as possible. While the boiler is being filled, add caustic soda in sufficient quantities to maintain a pH reading of 9.5 to 11. Additionally, add approximately 0.03-0.06 pounds of sodium sulfite per 1,000 gallons of boiler holding capacity to maintain 30-60 ppm.

Boiler Water Treatment Chemicals, Feed, and Contr

Boiler Water Treatment Chemicals, Feed, and Control - Perhaps It Is More Complicated Than We Thought - Dave Christophersen CROWN Solutions, Inc. September 15, 2006 Chemicals used to treat steam boiler systems are applied based upon the demand and mode of reaction of each chemical used.

How to Estimate the Right Size of Gas Boilers for t

Dec 27, 2018· Multiply your square footage by 50 to determine the size of your boiler. For instance, if you house is 1,103 square feet, your heater should be at least 55,150 Btu. Things You Will Need.

DRAFT BOILER/FEEDWATER GUIDELIN

In a steam boiler system, there are three potentially destructive elements: oxygen, carbon dioxide, and solids. 2.2.2 As the boiler water is heated and changes to steam, free oxygen is released, carbon dioxide is released from the solids, and the solids drop out (precipitate). 2.2.3 As the steam is used in the end process, it cools and condenses

Boiler MACT, 40 CFR Part 63, Subpart DDDDD (5D) Questi

A hot water heater with a capacity of 120 gallons or less or a hot water boiler (e.g. not generating steam) with heat input capacity of less than 1.6 MMBtu/hr burning oil, biomass, or gas, is not covered under the rule under the definition of hot water heater. Q19. Is a boiler used for comfort heat located at an industrial facility covered

BOILERS | Energy-Models.c

Fire tube or "fire in tube" boilers; contain long steel tubes through which the hot gasses from a furnace pass and around which the water to be converted to steam circulates. (Refer Figure 2.2). Fire tube boilers, typically have a lower initial cost, are more fuel efficient and easier to operate, but they are limited generally to capacities of 25 tons/hr and pressures of 17.5 kg/cm 2.

Boiler Formulas - Johnston Boil

File Size: 99KB Boiler Horsepower What is the boiler horsepower of a boiler generating 21,500 lbs of steam per hour at 155 psi? The factor of evaporation is 1.08. BHP = (LB/HR*fe)/34.5 BHP Boiler Horsepower BHP = (LB/HR*fe)/34.5 Lb/Hr Pounds per Hour BHP = 21500 * 1.08 / …

Boiler Capacity - Engineering ToolB

Boiler load - the capacity of a steam boiler - is often rated as boiler horse powers, lbs of steam delivered per hour, or BTU. Lbs Steam delivered per Hour. Large boiler capacities are often given in lbs of steam evaporated per hour under specified steam conditions. BTU - British Thermal Units

ENERGY STAR Most Efficient 2020 — Boilers | Produc

ENERGY STAR Most Efficient 2020 — Boilers. Navien’s NCB is the first high efficiency compact wall-hung condensing combi-boiler with the capacity to supply both heat (up to 120k BTU/h) and domestic hot water (up to 199k BTU/h) for a whole house. Takes up 80% less space than a traditional floor standing boiler and storage tank.

Effect of Thermal Storage on the Performance of a Wo

In the residential application the load varies strongly over the course of a year and a high fraction of the load is typically under 15% of the maximum boiler capacity. Thermal storage can be used even with boilers which have modulation capacity typically to 30% of the boiler maximum.

Anatomy of a Package-Boiler Project | HPAC Engineeri

What is the required steam capacity? Often, the most important question regarding emissions limits concerns NOx. Some regions require 9 ppm of NOx, although many are moving to 5-ppm limits. and commission a boiler. One way to begin this phase is with a diagram communicating the key requirements for both the water side and the fuel

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration

Copyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.

top