MENU
products
  1. Home
  2. --
  3. Industrial boilers

Boiler Heating Surface Standard Per Kg Of Steam

Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

What is the capacity of a boiler if its heating surfa

File Size: 1MB Jun 03, 2018· Assume boiler with dimensions 10 x 10 x 20 surface is 10 x 10 x 2 = 200 and 10 x 20 x 4 = 800 total 1000 SM volume is 10 x 10 x 20 = 2000 M^3

Exploring ThE MyTh of BoilEr hEaTing SquarE fooTa

The engineers had created a boiler that has a longer pressure vessel life than boilers that maintain at least 5 sq. ft. of heating surface per horsepower, with a boiler design that defies the century-old “rule of thumb.” In addition to the extended life, the boiler has a smaller footprint and lower shipping cost. BoilEr hEaTing SquarE fooTagE

convert boiler heating surface to horsepower – CFBC Boil

Keyword: CFBC Boiler Manufacturer, convert boiler heating surface to horsepower FAQ about convert boiler heating surface to horsepower 1.Why choose ZG as convert boiler heating surface to horsepower manufacturer? We have over 70 years' experience of industrial steam boiler and autoclave,and we have a professional installation and after-sales staff for products.Take advantage of the most

Steam Heating Process - Load Calculati

In general steam heating is used to. change a product or fluid temperature; maintain a product or fluid temperature; A benefit with steam is the large amount of heat energy that can be transferred. The energy released when steam condenses to water is in the range 2000 - 2250 kJ/kg (depending on the pressure) - compared to water with 80 - 120 kJ/kg (with temperature difference 20 - 30 o C).

Boiler Capacity Calculation with Heating Surface Area--Z

hp is calculated by the blr mfr but probably have 400 to 600 hp if you calc 5 sfhs to 8 sfhs per bhp. newer boilers are squeezed to 5 or 6 sfhs/b1Steam generating capacity can be determined from heating surfaces on a FT boilers but w/WT boilers the steaming capacity determination is a littleSpirax Sarco has a module on boiler ratings and boiler horsepower in their website learning centre. Block 3, module 3.5 I think. Not too sophisticaSince Your D-type WT boiler has water-cooled metallic walls,the average heat release in the furnace is 30,000 btu/hr per cu.ft. of furnace volume fRat, How about something really approximate such as comparing outside dimensions to modern D-type boilers ? In my opinion, if I have a "box" with t Boiler Capacity Calculation with Heating Surface Area 2018-09-29 11:00:44. 1 ton steam boilers generate 600,000 calories of heat, according to the standard per square meter of building (residential, office, hotel, etc.) heating 100 calories, so a ton of steam boiler standard heating area of 600000 /100 = …

Boiler Sizing | Weil-McLa

File Size: 139KB Name Description Boiler Replacement Guide Step-By-Step Procedures For Properly Sizing Hot Water And Steam Replacement Boilers For Homes And Small Commercial Buildings Easy-Loop Booklet Simplified Procedures For Designing An Easy-Loop Hydronic Heating System Using Weil-McLain® Boilers, Convector Baseboard, And Series-Loop Piping

How do you calculate heating surface of a steam boil

Jan 16, 2007· so question,, what is the heating surface area of a boiler with 21 tubes, 2.5" in diam, 16' long. the calculation will look like this. diam x pi x (16' x 12") x 21 divided by 144. 2.5 x 3.1416 x 192 x 21 divided by 144. 2.5 x 3.1416 x 192 x 21 = 31667.328 . 31667.328 divided by 144 = 219.91

Boiler Horsepower - Engineering ToolB

Boiler horsepower - a power unit from the 19 th-20 th centuries - was used to rate the capacity of a boiler to deliver steam to steam engines.. A common definition of one boiler horsepower is the amount of energy required to produce 34.5 pounds (15.65 kg) of steam per hour at pressure and temperature 0 psig (0 bar) and 212 o F (100 o C) - with feed water at pressure 0 psig and temperature 212 o F.

boiler heating surface area formula – Industrial Boil

File Size: 881KB Exploring ThE MyTh of BoilEr hEaTing … defined as 10 sq. ft. of boiler heating surface. … of boilers and recommend a standard for heating surface area per boiler … Industrial Boiler Sellers and Manufacturer | We Supply … boiler heating surface area formula. by zgboilersummer. How can you calculate heating surface area fire tube boiler?

Boiler – Fundamentals and Best Practic

Steam Production When heat is added to water, its temperature rises at a rate of 0.56°C (1°F) for each heat input of 2.095 kJ/kg (1 Btu/lb) If we take water at 0°C (32°F) and we

Determining Boiler Capacity from Heating Surface Ar

Dec 10, 2004· At 100% rating, for WT. boilers, steaming rate is 3 1/2 lbs saturated steam per sq.ft of heating surface, however dont us this value since WT boiler will produce steam well over 100% rating.For example,a horizontal WT boiler can generate 15.1 to 22.5 lbs of saturated steam per sq ft of H.S..

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration

Copyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.